PROJECT 2: WEEK 13
PROJECT 2: WEEK 13
Good afternoon EVERYONE :)
Although there are some challenges we need to face last week, but we yet to defeat it!
After testing for countless times in these few weeks,from 10 am to 6 pm, we have successfully discover the current that use for lithography process ,which is 130 mA. According to the title and question gave by Dr Woon for project 2, after using the laser engraver machine to perform lithography, the next step we need to do is to determine the smallest size that can be pattern.
We have tried out different diameter of the straight line, various length of the gap between the two lines. Both of this require a software named Inkscape to design and apply. We have change the diameter to smaller and smaller. the diameter of the line is decrease form 0.1000 mm to 0.035mm whjile the gap between the line is gradually diminish from 5mm to 4mm or even smaller. We are still determining the smallest gap size between the lines.
Figure 1 : Lines with diameter 1.000 mm and larger gap size
Figure 2: Lines with 0.035 mm and smaller gap size
After the process of developing and post bake, here is the results we get.
Figure 3: Results obtain
Since we cannot see clearly the smallest gap size by our naked eye, Dr Woon had borrowed a polarizing microscope done by our coursemate for better view.
Figure 4: This is the polarizing microscope
With the microscope we can have a better and clearer view of our result.
Figure 5 : Results view under the polarizing microscope
That's all for this week.
We will work hard to get the smallest gap between the lines :)